Home >  Products > Data Center Infrastructure > UPS> Online Transformerless Commercial UPS> UB (1-3kVA)
UB
1-3kVA
 
UB series power supply adopts online double conversion design and digital control technology and it features high input and output power factor(0.9). With ECO mode for energy-saving, intelligent battery management and excellent network management, it is a cost-effetive power solution for your critical devices. When UPS is on battery mode, it can shut down unnecessary load and extend the backup time of the critical load.
General Features

● True double-conversion

● Digital control guarantees high reliability

● ECO mode operation for energy saving

● Output receptacle control for non-critical load shedding capability

● Emergency power off function(EPO)

● Generator compatible

● Communications:RS-232,USB,SNMP card(Optional), Relay card (Optional)

● Bypass can be used when UPS is off(Setted in LCD)

● Cold start

Technical Specification
MODEL UB
10-24
UB
10
UB
10L
UB
15
UB
15L
UB
20-48
UB
20
UB
20-96
UB
20L
UB
20L-96
UB
30
UB
30-96
UB
30L
UB
30L-96
Capacity
(VA/Watts)
1000VA/900W 1500VA/1350W 2000VA/1800W 3000VA/2700W
INPUT 
Nominal
Voltage
 208/ 220/230/240Vac(L+N+PE)
Operating
 Voltage
Range
110~300Vac @(0~60%) Load;120~300Vac @(60~70%)Load,140~300Vac @(70~80%)Load;
160~300Vac @(80~100%)Load
Operating
 Frequency
Range
50Hz:45~55Hz,60Hz: 55-65Hz  Auto Sensing
Power Factor  > 0.85@25%Load;>0.95 @50%Load;>0.97@75%Load;>0.99 @ Nominal voltage& 100%Load
OUTPUT  
Output Voltage 208/220/230/240Vac:230Vac(Default)
Power Factor 0.9
Voltage
 Regulation
±1%
Frequency Synchronized
 Range
45-55Hz ±0.02Hz@ 50Hz, 55-65Hz ±0.02Hz@60Hz
Battery Mode
&None  
Synchronized Range 
(50/60±0.02)Hz
Crest Factor 3:1
Harmonic
Distortion
(THDv)
≤3% with linear load
≤5% with non-linear load 
Waveform  Pure Sinewave
Transfer Time Utility to Battery : 0ms; Utility to Bypass: 4ms(Typical)
EFFICIENCY
AC Mode 88% 88% 89% 90%
Battery Mode 84% 85% 85% 85% 86% 87%
ECO Mode >93% >94%
BATTERY
Battery Type 12V/9AH 12V 12V/9AH 12V 12V/9AH 12V/7AH 12V 12V/9AH 12V/7AH 12V
Numbers 2 3 3*N 3 3*N 4 6 8 6*N 8*N 6 8 6*N 8*N
Maximum
 Charging
 Current (A)
1.0 6.0/12.0 1.0 6.0/12.0 1.0 6.0/12.0 1.0 6.0/12.0
Charging
 Voltage(Vdc)
27.4V±1% 41.1V±1% 41.1V
±1%
54.8±1% 82.2V±1% 109.6V±1% 82.2V±1% 109.6V±1% 82.2V±1% 109.6V±1% 82.2V±1% 109.6V±1%
Protect Over-voltage(14.7v) /Low-voltage(10v)
PROTECTION
Overlo ad 
Capacity
Line Mode 105%-150%, 30s turn to bypass mode ; >150% 300ms turn to bypass mode
Battery Mode 105%-150%, exceed 30s shutdown ;  >150% exceed 300ms shutdown
INDICATORS
LED & LCD Display Load/Battery/Input/Output/Operating Mode Information
ALARM
Battery Mode Sounding every 4 seconds 
Battery Low Sounding every second
Overload Sounding every 0.5 second
Fault Continuously Sounding
MANAGEMENT
Smart RS-232/USB
(Preferential)
External Modbus card supported by RS232,Software supports Windows Family,Linus,FreeBSD
Intelligent Slot SNMP (Standard or mini) independent to RS-232(Optional)
ENVIRONMENT
Operating
Temperature
0℃~40℃
Humidity Range 0~95% (Non-condensing)
Altitude < 1500m
Noise Level <50dB@ 1Meter
PHYSICAL
Dimension
 W×D×H (mm)
144×400×215 191×468×337
Net Weight (kg) 11.3 13.7 5.9 13.9 6.2 21.9 26.9 29.6 10.6 10.8 27.4 30.1 11.1 11.3
STANDARDS
Safety  IEC/EN62040-1
EMC IEC/EN62040-2