UID
10-120kVA
Embedded with isoltated transformer, UID three-phase UPS solution raging from 10kva-120kva are designed for harsh environment especially industrial application.With high power factor up to 0.97,full DSP control and online double conversion design,it can offer high levels of reliability and protection for industrial facilities and mission critical systems, nsuring maximum power reliability.
General Features
● Online double conversion
● Full DSP control
● High power factor:0.9
● Wide input adaptability:(380Va/400Vac/415Vac) (-25%/+20%)
● Optimized battery management,self-test&lexible battery configuration
● N+X parallel redundancy
● Strong overload capability:110%/125%/150% overload for 60/10/1min.
● Power walk in
● Generator mode
● LBS synchronization
● Multi-protection
● User-friendly network management
Technical Specification
MODEL | EP10-L | EP20-L | EP30-L | EP40-L | EP60-L | EP80-L | EP100-L | EP120-L | EP160-L | ||
Capacity (VA/Watts) |
10kVA / 8kW | 20kVA / 16kW | 30kVA / 24kW | 40kVA / 32kW | 60kVA /48kW | 80kVA/ 64kW | 100kVA/ 80kW | 120kVA/ 96kW | 160kVA/ 128kW | ||
INPUT | |||||||||||
Operating voltage range |
380/400/415Vac (-25% / +20% ), (3Ph+N+PE) | ||||||||||
Operating frequency range |
50/60Hz(±5%) | ||||||||||
Power Factor | >0.97 (with filter) | ||||||||||
OUTPUT | |||||||||||
Output Voltage | 380/400/415Vac (±1%) | ||||||||||
Output frequency | 50/60Hz (±0.05%) | ||||||||||
Harmonic Distortion (THDv) |
<3% with linear load | ||||||||||
Crest factor | 3:1 (max) | ||||||||||
Efficiency | ≥90.5% | ≥91.5% | |||||||||
BYPASS | |||||||||||
Rated voltage | 380/400/415Vac | ||||||||||
Rated frequency | 50/60Hz(auto-sensing) | ||||||||||
Voltage protection range |
Upper limit: +20% (+10%,+15%,+20% adjustable) Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) |
||||||||||
Frequency protection range |
±10% (±2.5%, ±5%,±10%, ±20% adjustable) | ||||||||||
BATTERY | |||||||||||
Battery voltage | 384Vdc ( 360~384Vdc ) | ||||||||||
SYSTEM FEATURES | |||||||||||
Transfer time | 0ms (Line mode →Battery mode) | ||||||||||
Overload | ≤110%/60min ,≤125%/10min ,≤150%/1min,to Bypass | ||||||||||
LED display | Input, Inverter, Bypass, Battery, Output, Status | ||||||||||
LCD display | I/O voltage, frequency, power, power factor, battery voltage, current, battery status, load percentage, UPS status, history record |
||||||||||
Communication interface |
Dry contact, RS232, RS485, SNMP card (Optional) | ||||||||||
Optional | Harmonic filter, SNMP adapter, LBS cables, battery temperature sensor,Bypass current-sharing inductor | ||||||||||
ENVIRONMENT | |||||||||||
Operating Temperature |
0℃~40℃ | ||||||||||
Storage temperature |
-25~55℃ | ||||||||||
Humidity range | 0~95% (non-condensing) | ||||||||||
Altitude | <1500m | ||||||||||
Noise level | <58dB | <65dB | |||||||||
PHYSICAL | |||||||||||
Dimension W×D×H (mm) |
350×650×1050 | 430×830×1100 | 720×675×1400 | 890×775×1600 | |||||||
Net weight (kg) | 148 | 163 | 230 | 255 | 386 | 426 | 625 | 685 | 780 | ||
STANDARDS | |||||||||||
Safety | IEC/EN 62040-1;IEC/EN 60950-1 | ||||||||||
Performance | IEC 62040-3 | ||||||||||
EMC | IEC/EN 62040-2;IEC 61000-2-2;IEC 61000-4-2;IEC 61000-4-3;IEC 61000-4-4; IEC 61000-4-5;IEC 61000-4-6;IEC 61000-4-8;IEC 61000-4-11; |