EP-IND-ZY 
10-20kVA

EP-IND-ZY is a three-phase in one-phase out online transformer-bansed industrial UPS. With anti harsh environment design,EP-IND-ZY serious industrial UPS has strong impact resistance(IP grade 31)and can be scaled to meet changing electrical requirements and is adaptable to the most stringent technical specification. It support the continuing demand from downstream refining and petrochemicals, upstream oil and gas, power generation, large steel plants, metallurgy & cnooc, nuclear power and the growing regulatory and safety needs of today’s industrial complexes.

General Features

● 12 pulse rectifier technology

●3Phase In/1phase Out 

Input/output galvanic isolation

IP31 

Input voltage window 300~500Vac and input frequency window 45~65Hz 

DC Input 220dc (-25%~+30%) 

Advance Battery auto float/boost charger, battery temperature compensation

N+X parallel redundancy 

110%/125%/150% overload for 60min/10min/1min

Power Walk in 

Load Bus Synchronization(LBS) 

5.7” or 7” touch-screen color monitor 

RS232, RS485(ModBus), Optional SNMP, Eight Dry contact Signals, Circuit breaker status, battery temperature sensor, etc.

Full range from 10kVA up to 120kVA 

Perfect for oil and gas, refining, chemical, industrial power, power transmission and distribution, metallurgy, automotive, glass

● High power factor

● Wide input adaptability

● Optimized battery management

● N+X parallel redundancy

● Strong overload capability

● Generator mode

● Multi-protection

● EPO function

● User-friendly network management

Technical Specification

 
MODEL EP-IND10
-ZY
EP-IND15
-ZY
EP-IND20
-ZY
EP-IND30
-ZY
EP-IND40
-ZY
EP-IND50
-ZY
EP-IND60
-ZY
EP-IND80
-ZY
EP-IND100
-ZY
EP-IND120
-ZY
Capacity(kVA/kW) 10/8 15/12 20/16 30/24 40/32 50/40 60/48 80/64 100/80 120/96
INPUT
Nominal voltage & range(Vac) 380/400/415  (3Ph+PE,  without N)(±25%)
Frequency & range(Hz) 50/60(±10%)
BYPASS INPUT
Norminal voltage(Vac) 220/230/240
Frequency tollerance (Hz) ±2Hz(0.5  , 1 , 2 , 3Hz settable)
OUTPUT
Voltage (Vac) 220/230/240±0.5% (L+N+PE)
Frequency 50/60(0.5%)
Waveform Pure Sinewave THDV≤1%(100%  Linear  load)
Transfer time(ms) 0
Efficiency(%) Up to 94%
Overload 110%  overload for 60min;≤125%  lasting 10min;≤150%  lasting 1min
DC(BATTERY) 
DC voltage(Battery)(Vdc) 220 VDC
ENVIRONMENTAL
Operating temperature(℃) -5~40℃
Storage temperatue(℃ ) -20~+55℃(no  battery , at least keeping 4Hours to make the operation temperature up to 0℃ after -20℃  storage)
Humidity range 20~95%(non  condensing)
Altitude ≤1500m. Refer to GB/T 7260.3 standard to execute derating when altitude is more than 1500m
Noise level(dB) 58 60 62
OTHERS
Alarm function Output overload , utility abnormal , DC(battery)low , UPS fault alarm & history , etc
Protection function Short circuit, overload , over temperatue , DC(battery)low , output low voltage , fan fault alarm
Communication function RS232 , RS485(Modbus),  SNMP(Optional),  Dry contact car , Breaker status , Battery Temperature sensor
PHYSICAL
Dimension(W×D×H)mm 800×800×1800(2260  for IP31) 1000×800×1800(2260 for IP31) 1400×800×1800(2260 for IP31)
Weight(kg) 535 550 570 610 705 860 960 1160 1560 1650
STANDARDS IEC 62040-2 CLASS C3   IEC60905-1 , IEC 6240-1-1 , UL1778 , IEC62040-3