Industrial UPS-UID Family
100-800kVA
UID Series UPS is a three-phase in, three-phase out on-line double conversion UPS with a transformer isolated
inverter. With DSP control, high power factor 0.97 and high efficency 94%, it can provide maximum protection the ultimate power protection for “mission critical” applications: data processing, tele-communications, industrial processes, security and electro-medical systems.
General Features
● Online double conversion
● Full DSP control
● High power factor
● Wide input adaptability
● Optimized battery management
● N+X parallel redundancy
● Strong overload capability
● Power walk in
● Generator mode
● Multi-protection
● EPO function
● User-friendly network management
Technical Specification
MODEL | UID100 | UID120 | UID160 | UID200 | UID300 | UID400 | UID500 | UID600 | UID800 | ||
Capacity (VA/Watts) |
100kVA / 90kW | 120kVA / 108kW | 160kVA / 144kW | 200kVA / 180kW | 300kVA / 270kW | 400kVA/ 360kW | 500kVA/ 450kW | 600kVA/ 540kW | 800kVA/ 720kW |
||
INPUT | |||||||||||
Operating voltage range |
380/400/415Vac (-25% / +20% ), (3Ph+N+PE) | ||||||||||
Operating frequency range |
50/60Hz(±5%) | ||||||||||
Power Factor | >0.97 (with filter) | ||||||||||
OUTPUT | |||||||||||
Output Voltage | 380/400/415Vac (±1%) | ||||||||||
Output frequency |
50/60Hz (±0.05%) | ||||||||||
Harmonic Distortion (THDv) |
<2% with linear load | ||||||||||
Crest factor | 3:1 (max) | ||||||||||
Efficiency | ≥92% | ≥92.5% | ≥93% | ≥93.5% | ≥94% | ||||||
BYPASS | |||||||||||
Rated voltage | 380/400/415Vac | ||||||||||
Rated frequency |
50/60Hz (auto-sensing) | ||||||||||
Voltage protection range |
Upper limit: +20% (+10%,+15%,+20% adjustable)Lower limit: -40% (-10%, -20%, -30%, -40% adjustable) | ||||||||||
Frequency protection range |
±10% (±2.5%, ±5%,±10%, ±20% adjustable) | ||||||||||
BATTERY | |||||||||||
Battery voltage |
384Vdc ( 360~408Vdc ) | 480Vdc | 600Vdc | ||||||||
SYSTEM FEATURES | |||||||||||
Transfer time | 0ms (Line mode →Battery mode) | ||||||||||
Overload | Load≤110%/60min ,≤125%/10min ,≤150%/1min,to Bypass | ||||||||||
LED display | Input, Inverter, Bypass, Battery, Output, Status | ||||||||||
LCD display | I/O voltage, frequency, power, power factor, battery voltage, current, battery status, load percentage, UPS status, history record, settings |
||||||||||
Communication interface | Dry contact, RS232, RS485, SNMP card (Optional) | ||||||||||
Optional | Harmonic filter, SNMP adapter, LBS cables, battery temperature sensor,Bypass current-sharing inductor | ||||||||||
ENVIRONMENT | |||||||||||
Operating Temperature |
0℃~40℃ | ||||||||||
Storage temperature |
-25~55℃ | ||||||||||
Humidity range |
0~95% (non-condensing) | ||||||||||
Altitude | <1500m | ||||||||||
Noise level | <65db | <70dB | |||||||||
PHYSICAL | |||||||||||
Dimension W×D×H (mm) |
890×775×1600(6P) 1515×830×1600(12P) |
1200×800×1600(6P) 1400×1000×1900(12P) |
1400×1000×1900(6P) 1640×1000×1900(12P) |
2580×1000×1900(500)12P 2800×1040×1900(600)12P |
3280×1040 ×1950(12P) | ||||||
Net weight (kg) |
625/1300 | 685/1450 | 1219/1774 | 1030/1715 | 1560/2395 | 1640/2510 | 3510 | 3950 | 4950 | ||
Shipping weight (kg) |
695/1370 | 755/1520 | 1349/1954 | 1130/1845 | 1690/2545 | 1770/2665 | 3730 | 4250 | 5245 | ||
STANDARDS | |||||||||||
Safety | IEC/EN62040-1;IEC/EN60950-1 | ||||||||||
Performance |
IEC 62040-3 | ||||||||||
EMC | IEC/EN62040-2;IEC 61000-2-2;IEC61000-4-2;IEC61000-4-3;IEC61000-4-4; IEC61000-4-5;IEC61000-4-6;IEC61000-4-8;IEC 61000-4-11; |