● High efficiency and energy saving
When the outdoor environment temperature is low, shut down the compressor to fully use of natural cold source and reduce energy consumption
Fluorine pump free-cooling precision air conditioner use high efficiency and energy saving parts, so it has the advantage of environmental protection and energy saving as the KSTAR other precision air conditioner product
● High reliability
Use high quality parts which have great performance over time
Advanced and reliable controller ensures that the unit switches the cooling mode automatically, various protection functions ensure the unit running safely and reliably
● Easy to use
Highly integrated and modular design, easy to install and maintain
Intelligent communication ports
FS*** | Unit | 20 | 25 | 40 | |
Unit configuration | - | Single cool | Single cool | Single cool | Constant temperature constant humidity |
Compressor Total Cooling Capacity1) | kW | 25.1 | 25.5 | 40.4 | |
Fluorine pump Total Cooling Capacity2) | kW | 25.5 | 27.5 | 40.8 | |
Compressor Sensible Cooling Capacity1) | kW | 25.1 | 25.5 | 40.4 | |
Fluorine pump sensible Cooling Capacity1) | kW | 25.5 | 27.5 | 40.8 | |
Air volume | m³/h | 4920 | 5050 | 8080 | |
Compressor Sensible heat ratio | / | 1 | 1 | 1 | |
Fluorine pump sensible heat ratio | / | 1 | 1 | 1 | |
Heating capacity | kW | - | - | - | 6 |
Humidifying capacity | kg/h | - | - | - | 3 |
Number of compressors | Pcs | 1 | 1 | 1 | |
Number of fans | Pcs | 6 | 3 | 3 | |
Voltage | V | 380 | 380 | 380 | |
Frequency | Hz | 50 | 50 | 50 | |
Phase | Pcs | 3 | 3 | 3 | |
Full-load current | A | 26 | 28.1 | 32.7 | 41.8 |
Unit Weight | kg | 240 | 265 | 315 | 325 |
Unit length | mm | 300 | 400 | 600 | |
Unit width | mm | 1100 | 1100 | 1100 | |
Unit height | mm | 2000 | 2000 | 2000 | |
Single energy saving module width | mm | 728 | |||
Single energy saving module depth | mm | 580 | |||
Single energy saving module height | mm | 2026 | |||
NOTE 1.Parameter table 1)Compressor cooled data based on 37℃,50% RH indoor return air temperature 2)Fluorine pump data based on 37℃,25% RH indoor return air temperature 2. Specifications are subject to change without prior notice |
KCS*** | Unit | 32 | 36 | 54 |
Heat exchanging | kW | 31 | 36.8 | 54.4 |
Voltage | V | 220 | 220 | 220 |
Frequency | Hz | 50 | 50 | 50 |
Phase | Pcs | 1 | 1 | 1 |
Full-load current | A | 2.7 | 2.7 | 5.4 |
Noise1) | dB(A) | 54.1 | 50.7 | 52.1 |
Unit Weight | kg | 125 | 138 | 165 |
Unit length | mm | 1601 | 1801 | 1801 |
Unit width | mm | 975 | 975 | 1274 |
Unit height | mm | 651 | 651 | 651 |
Foot stool height | mm | 455 | 455 | 455 |
Note: 1.Parameter table 1)The noise data is sound pressure level value of 10m free field 2.Specifications are subject to change without prior notice |