General Features
●High efficiency and energy saving
When the outdoor environment temperature is low, shut down the compressor to fully use of natural cold source and reduce energy consumption;
Fluorine pump free-cooling precision air conditioner use high efficiency and energy saving parts, so it has the advantage of environmental protection and energy saving as the KSTAR other precision air conditioner product.
●High reliability
Use high quality parts which have great performance over time;
Advanced and reliable controller ensures that the unit switches the cooling mode automatically, various protection functions ensure the unit running safely and reliably.
●Easy to use
Highly integrated and modular design, easy to install and maintain;
Intelligent communication ports
MT***UR/DR | Unit | 25 | 30 | 35 | 45 | 55 | 40 | 50 | 60 | 70 | 80 | 90 | 100 |
AC Fan | |||||||||||||
Compressor Total Cooling Capacity1) | kW | 26.7 | 30.8 | 35.5 | 45.5 | 54.5 | 41.2 | 53.5 | 61.4 | 70.9 | 81.3 | 90.6 | 104.4 |
Fluorine pump Total Cooling Capacity2) | kW | 26.3 | 30.4 | 35.3 | 45.1 | 54.3 | 40.5 | 52.9 | 61.1 | 70.5 | 80.9 | 90.2 | 104.1 |
Compressor Sensible Cooling Capacity1) | kW | 24.3 | 29.3 | 32.7 | 42.8 | 51.8 | 37.9 | 49.2 | 57.7 | 63.8 | 77.2 | 83.4 | 95 |
Fluorine pump sensible Cooling Capacity2) | kW | 24.2 | 28.6 | 32.5 | 41.9 | 50.5 | 37.7 | 49.2 | 56.8 | 64.9 | 76.1 | 83 | 95.8 |
Air volume | m³/h | 7500 | 8000 | 8500 | 13000 | 15000 | 12500 | 14000 | 18000 | 18500 | 21000 | 23000 | 25000 |
Compressor Sensible heat ratio | / | 0.91 | 0.95 | 0.92 | 0.94 | 0.95 | 0.92 | 0.92 | 0.94 | 0.9 | 0.95 | 0.92 | 0.91 |
Fluorine pump sensible heat ratio | / | 0.92 | 0.94 | 0.92 | 0.93 | 0.93 | 0.93 | 0.93 | 0.93 | 0.92 | 0.94 | 0.92 | 0.92 |
EC Fan | |||||||||||||
Compressor Total Cooling Capacity1) | kW | 26.9 | 31.2 | 35.7 | 45.9 | 54.7 | 41.6 | 53.8 | 61.7 | 71.1 | 81.8 | 90.8 | 104.7 |
Fluorine pump Total Cooling Capacity2) | kW | 26.7 | 30.9 | 35.7 | 45.5 | 55.6 | 41.1 | 53.3 | 61.5 | 70.9 | 81.3 | 90.6 | 104.5 |
Compressor Sensible Cooling Capacity1) | kW | 25 | 30 | 33.6 | 44.1 | 52.5 | 39.5 | 50.6 | 59.2 | 66.1 | 78.5 | 85.4 | 97.4 |
Fluorine pump sensible Cooling Capacity2) | kW | 24.8 | 29.4 | 33.2 | 42.8 | 52.3 | 38.6 | 50.1 | 58.4 | 65.9 | 77.3 | 84.3 | 97.2 |
Air volume | m³/h | 7800 | 8300 | 8800 | 13500 | 15400 | 13200 | 14600 | 18700 | 19300 | 21600 | 23900 | 26000 |
Compressor Sensible heat ratio | / | 0.93 | 0.96 | 0.94 | 0.96 | 0.96 | 0.95 | 0.94 | 0.96 | 0.93 | 0.96 | 0.94 | 0.93 |
Fluorine pump sensible heat ratio | / | 0.93 | 0.95 | 0.93 | 0.94 | 0.94 | 0.94 | 0.94 | 0.95 | 0.93 | 0.95 | 0.93 | 0.93 |
Heating capacity(Standard) | kW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 |
Heating capacity(Max) | kW | 12 | 12 | 12 | 18 | 18 | 18 | 18 | 18 | 18 | 24 | 24 | 24 |
Humidifying capacity (Standard) | kg/h | 6 | 8 | 8 | 10 | 10 | 10 | 10 | 10 | 10 | 12 | 12 | 12 |
Humidifying capacity (Max) | kg/h | 8 | 8 | 8 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Number of compressors | Pcs | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Number of fans | Pcs | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 |
Full-load current | A | 32 | 35.9 | 38.3 | 51.5 | 57.6 | 50.3 | 60.1 | 65.2 | 70 | 82.8 | 88.2 | 103.4 |
Unit Weight | kg | 390 | 460 | 470 | 620 | 630 | 690 | 720 | 780 | 790 | 990 | 1010 | 1110 |
Unit Length | mm | 850 | 1200 | 1200 | 1650 | 1650 | 1650 | 1650 | 2010 | 2010 | 2460 | 2460 | 2810 |
Unit depth | mm | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 |
Unit Height | mm | 1960 | 1960 | 1960 | 1960 | 1960 | 1960 | 1960 | 1960 | 1960 | 1960 | 1960 | 1960 |
Single energy saving module width | mm | 728 | |||||||||||
Single energy saving module depth | mm | 580 | |||||||||||
Single energy saving module height | mm | 2026 | |||||||||||
NOTE 1. Parameter table 1) Compressor cooled data based on 24℃,50% RH indoor return air temperature 2) Fluorine pump data based on 24℃,50% RH indoor return air temperature 2. The power supply type:380~415V / 3P / 50Hz 3. Specifications are subject to change without prior notice |
KCS*** | Unit | 24 | 28 | 32 | 36 | 42 | 48 | 54 | 64 |
Heat exchanging | kW | 23.8 | 27.2 | 31 | 36.8 | 42.2 | 47.6 | 54.4 | 62.4 |
Voltage | V | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 |
Frequency | HZ | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
Phase | Pcs | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Full-load current | A | 2.7 | 2.7 | 2.7 | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 |
Noise1) | dB(A) | 54.9 | 52.9 | 54.1 | 50.7 | 53 | 52 | 52.1 | 55.1 |
Unit Weight | kg | 117 | 124 | 125 | 138 | 143 | 152 | 165 | 185 |
Unit length | mm | 1601 | 1401 | 1601 | 1801 | 1801 | 1801 | 1801 | 2001 |
Unit width | mm | 975 | 975 | 975 | 975 | 975 | 1274 | 1274 | 1274 |
Unit height | mm | 651 | 651 | 651 | 651 | 651 | 651 | 651 | 651 |
Foot stool height | mm | 455 | 455 | 455 | 455 | 455 | 455 | 455 | 455 |
Note: 1.Parameter table 1)The noise data is sound pressure level value of 10m free field 2.Specifications are subject to change without prior notice |